Distribution Silicone Products
Designed to meet all specifications required to ensure a maximum level of protection.
Midsun’s wildlife outage covers are carefully engineered to prevent weather and animal related outages throughout substations, transmission and distribution lines.
We want to make sure that you receive the best solution for your animal mitigation problem.
Our products are not constricted by extreme temperature, harsh environments or odd connections & shapes. Regardless to where the animals are contacting, we have a cover that will fit and give you a combination of superior elements to provide a long-term solution.
Midsun can provide turnkey operations for our E/Products. If you are looking to train your staff, one of our OSHA certified applicators will give a full demonstration.
Installing our products can save your company money, time & aggravation.
E/INSULATION
E/Insulation is a silicone hose used to protect a variety of distribution and substation equipment at 20kV phase-to-ground. The E/Insulation is manufactured with a split seam to allow for an easy application without the need of breaking electrical connections.
There is no heat shrinking required for application and no tools other than a cutting tool for proper length are needed.
Product Feature
Colors
Gray and Orange*
Angle bus, flat bus and round bus are only available in gray.
Part # - Size - Conductor Size - Conductor OD
E/INS-025-G – .25 in. (6.35 mm) – .250 in (6.35 mm)
E/INS-050-G – .50 in. (12.7 mm) – .500 in (6.38 mm – 12.70 mm)
E/INS-075-G – .75 in. (19.05 mm) – 0.750 in (12.73 mm – 19.05 mm)
E/INS-100-G – 1.00 in. (25.4 mm) – 1.00 in (19.08 mm – 25.4 mm)
E/INS-125-G – 1.25 in. (31.75 mm) – 1.001 in – 1.25 in (25.65 mm – 31.75 mm)
E/INS-150-G – 1.50 in. (38.1 mm) – 1.251 in – 1.500 in (31.78 mm – 38.10 mm)
E/INS-175-G – 1.75 in. (44.45 mm) – 1.504 in – 1.735 in (38.20–44.07 mm)
E/INS-200-G – 2.00 in. (50.8 mm) – 1.980 (44.70 mm – 50.29 mm)
Angle Bus
E/INS-ABC-3.25″ Tail-G-60″ – 3.25 in (82.55 mm)
E/INS-ABC-4.00″ Tail-G-60″ – 4.00 in (101.60 mm)
Round Bus
E/INS-250G – 2.5 in (63.50 mm)
E/INS-350G – 3.5 in (88.90 mm)
E/INS-450G – 4.5 in (114.30 mm)
Flat Bus
E/INS-FLAT325G-5 – 3.25 in (82.55 mm)
E/INS-FLAT 400G-5 – 4.0 in (101.60 mm)
BUSHING COVER
Part Number: E/BC – Half
Drawing Number: 130-00-01
Phase-to-Ground: Up to 25 kV
Silicone Bushing cover designed to fit small station service transformer bushings, PT’s and CT’s, and pole top transformer bushings.
Part Number: E/BC – Small
Drawing Number: 210-00-01
Phase-to-Ground:Up to 25 kV
Silicone bushing cover designed to fit small station service transformer bushings, PT’s and CT’s, and pole top transformer bushings.
Part Number: E/BC – Side
Drawing Number: 180-00-02
Phase-to-Ground: Up to 25 kV
Silicone cover designed for reclosure bushings. Perforated bottom allows it to fit various sized bushings.
TERMINATION COVER
Part Number: E/Term-CV
Drawing Number: 164-20-01
Phase-to-Ground: Up to 25 kV
Silicone cover designed to cover underground termination bushings.
Part Number: E/BCTI – CV
Drawing Number: 244-10-01
Phase-to-Ground: Up to 25 kV
Bus cable termination insulation cover.
FUSE CUTOUT COVER
Part Number: E/FUSE CUT OUT
Drawing Number: 132-00-01
Phase-to-Ground: Up to 25 kV
Silicone cover designed for use on fuse cut out switches. Design allows for easy opening and closing of fuse.
Part Number: E/FUSE CUT OUT -LG
Drawing Number: 260-00-01
Phase-to-Ground: Up to 25 kV
Silicone cover designed for use on larger fuse cut out switches. Design allows for easy opening and closing of fuse.
PIN INSULATOR COVERS
Part Number: E/PIN INS CV – SM
Drawing Number: 126-00-02
Phase-to-Ground: Up to 25 kV
Silicone cover designed to protect against bird and animal contact on standard crossarm pin insulators.
Part Number: E/PIN INS CV – MED
Drawing Number: 126-00-03
Phase-to-Ground: Up to 25 kV
NEW SIZE. Silicone cover designed to protect against bird and animal contact on standard crossarm pin insulators.
Part Number: E/PIN INS CV – LG
Drawing Number: 126-00-01
Phase-to-Ground: Up to 25 kV
Silicone cover designed to protect against bird and animal contact on large crossarm pin insulators.
ARRESTOR COVERS
Part Number: E/SRG – ARR – CV
Drawing Number: 268-00-02
Phase-to-Ground: 25 kV
Silicone cover designed to fit taller lightning arrestors with a a pass through lead or pole top bushings.
Part Number: E/PT-ARRESTOR CAP
Drawing Number: 184-00-01
Phase-to-Ground: Up to 25 kV
Silicone cover designed for pole top right angle lightning arrestor.
Part Number: E/PT-LA RECLR-CV
Drawing Number: 262-00-02
Phase-to-Ground: Up to 25 kV
Silicone cover designed for pole top arrestors with a single lead at a right angle. It may also be used for pole top right angle bushings.
Part Number: E/PT-DL-LA RECLR CV
Drawing Number: 262-00-01
Phase-to-Ground: Up to 25 kV
Silicone cover designed for pole top arrestors with double leads at a right angle. It may also be used for pole top right angle bushings.
Part Number: E/PT-T-LA RECLR CV
Drawing Number: 262-00-03
Phase-to-Ground: Up to 25 kV
Silicone cover designed to fit either pole top bushings or lightning arrestors with a pass through lead.
SENSOR COVERS
Part Number: E/L-SENSOR CV
Drawing Number:247-00-01
Phase-to-Ground: 25 kV
Silicone cover designed for right angle recloser sensors.
Part Number: E/SRVSC
Drawing Number: 103-00-01
Phase-to-Ground: Up to 25 kV
Silicone T-shaped cover designed for use on recloser T-Sensors
*Siemens
CAPACITOR & CURRENT SENSOR COVER
Part Number: E/PT – CAPITOR CV
Drawing Number: 227-00-01
Phase-to-Ground: Up to 25 kV
Silicone cover designed to protect energized portion of capacitor bushings.
Part Number: E/CAP EMC BOOT
Drawing Number: 111-00-01
Phase-to-Ground: Up to 25 kV
Capacitor Boot
Part Number: E/CSS-CV
Drawing Number: 266-00-02
Phase-to-Phase: Up to 25 kV
Silicone cover designed to insulate the bottom sensor of a Fisher Pierce current sensor
Part Number: E/FPS
Drawing Number: 222-00-01
Phase-to-Ground: Up to 25 kV
Silicone cove designed to insulate the bottom sensor of a Fisher Pierce current sensor
*Fisher Pierce
POLE TOP TRANSFORMER COVER
Part Number: E/PT-Trans-CV
Drawing Number: 186-00-01
Phase-to-Ground: Up to 25 kV
Silicone cover designed to fit pole top bushing with hand wheels. The cover can be applied without having to break hand wheel lug connection.
E/SILICONE SHEET
Part Number: E/SS
Size: 24″ x 120″ (609.6 x 3048 mm) Silicone Sheet
Part Number: E/SS – 30
Size: 30″ x 120″ (762 x 3048 mm) Silicone Sheet
The E/Silicone Sheet is a high temperature vulcanized custom compound silicone sheet with a polyester fabric reinforcement. Made from 65 durometer silicone, almost 1/8″ thick, it is a roll that allows you to custom cut covers for unique phase-to-phase and phase-to-ground areas of substation and distribution equipment.
E/Silicone Sheets offer up to 25 kV phase-to-ground insulation.
Product Features